MAINTENANCE
WARNING: Always make sure battery is disconnected before servicing lifter.
INSPECTION SCHEDULE
Perform inspections routinely, according to the following frequency schedule:
Every-Lift Inspection
• Examine the vacuum pads and load surface for contamination or debris (see VACUUM PAD
MAINTENANCE to follow).
• Examine the vacuum pads, controls and indicators for visual damage (see VACUUM PAD
MAINTENANCE to follow).
• Test the battery for adequate charge (see BATTERY TEST to follow).
If a battery’s charge appears to be inadequate, charge and retest the battery (see BATTERY
RECHARGE to follow). If any other deficiency is detected during the inspection, correct it before
using the lifter and perform the Frequent Inspection to follow.
Frequent Inspection
(
following every 20-40 hours’ use; or whenever lifter is out of service for 1 month or more
)
• Examine the lifter’s structure for visual damage.
• Examine the vacuum system (including vacuum pads, fittings and hoses) for visual damage.
• Examine the air filter for conditions requiring service (see AIR FILTER MAINTENANCE to follow).
• Perform the VACUUM TEST to follow.
• Check for unusual vibrations or noises while operating the lifter.
If the lifter is equipped with a Remote Control System, perform the REMOTE CONTROL SYSTEM TEST
to follow.
If any deficiency is detected during the inspection, correct it before using the lifter and perform
the Periodic Inspection to follow.
Periodic Inspection
(
following every 250-500 hours’ use; or whenever lifter is out of service for 1 year or more
)
• Examine the entire lifter for external evidence of looseness, excessive wear, deformation,
cracks, excessive corrosion, dents to structural or functional components, cuts, or any
deficiency which might constitute a hazard.
• Inspect all parts of the electrical system for damage, wear or contamination that could
constitute a hazard, in compliance with all local codes and regulatory standards that are
relevant for the geographical region.
CAUTION: Be sure to use appropriate cleaning methods for each type of electrical
component, as specified by codes and standards. Improper cleaning
can damage components.